Asian Journal of Pharmaceutics
  Home  |  About us  |  Instructions  |  Search  |  Current issue  |  Archives  |  Submission  |  Subscribe  |  Contact  |  Login 
RESEARCH ARTICLE
Year : 2010  |  Volume : 4  |  Issue : 4  |  Page : 205-212

Development and validation of discriminatory dissolution procedure for poorly soluble glyburide


1 Department of Pharmaceutical Analysis, Bharathi College of Pharmacy, Karnataka;Faculty of Pharmacy, School of Pharmaceutical Sciences, Karpagam University, Coimbatore, Tamilnadu, India
2 Department of Pharmaceutical Chemistry, Manipal College of Pharmaceutical Sciences, Manipal University, Karnataka, India
3 Department of Pharmaceutics, J.S.S. College of Pharmacy, Rocklands, Ooty, India
4 Faculty of Pharmacy, School of Pharmaceutical Sciences, Karpagam University, Coimbatore, Tamilnadu, India

Correspondence Address:
Sachin K Singh
Department of Pharmaceutical Analysis, Bharathi College of Pharmacy, Bharathinagara, Maddur Taluk, Mandya Dist, Karnataka-571 422
India
Login to access the Email id


DOI: 10.4103/0973-8398.76744

Get Permissions

In the present study, parameters such as solubility, medium pH, surfactant type and dissolution behavior of formulations, influence of sink conditions, stability and discriminatory effect of dissolution testing were studied for the selection of a proper dissolution medium for glyburide (BCS Class II drug). Results of solubility data revealed that solubility increased with an increase in pH. Sink conditions were exhibited in the 0.05 M borate buffer pH 9.6, 0.05 M phosphate buffer pH 6.5 containing 0.1-2% (w/v) cetyl trimethyl ammonium bromide (CTAB) and 0.05 M phosphate buffer pH 7.4 containing 0.1-2% CTAB (w/v), respectively. The 0.05 M phosphate buffer at pH 6.5 containing 0.1% CTAB (w/v) with an agitation speed of 50 rpm (USP II) showed a more discriminating drug release profile when compared with 0.05 M phosphate buffer at pH 7.4 containing 0.1% CTAB (w/v) with an agitation speed of 75 rpm. The spiked samples have shown better recovery at 50, 100 and 150% levels. There was no degradation, as observed in the mass spectrum of recovered dissolution samples when compared with the mass spectrum of standard drug solution, which promised that the method was specific and can be used for routine Quality Control analysis as well as for assessment of formulation variables in future dissolution studies of glyburide.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed5805    
    Printed197    
    Emailed4    
    PDF Downloaded32    
    Comments [Add]    
    Cited by others 1    